The D1210 Battery pack can be used to power several models of ColorMaker series LED fixtures Fixture run time is calculated when fixture is at full intensity. Below is a quick reference table for each model of fixture.
Fixtures can also be calculated using formula below when fixtures will not be at full intensity.
10 / (.180 * % Blue) + (.180 * % Green) + (.180 * % Red)
What does it mean?
The D1210 is rated at 10 Amps Per Hour. Each Color on the DCR-54 will use 180 Ma or .180 Amps at full intensity. Use the Dimmer % to calculate the current that each color will use.
Example
DCR-54 is set to the Following. The % reading can be calculated using the CM-T10-PRO digital Display.
Red = 100 % - Green = 60 % - Blue = 20 %
Equation
10 / (.180 * 1.00) + (.180* .60) + (.180* .20)
10 / .180 +.108 +.036
10 / .324
30.8 Hours Run Time. The current draw at this setting is 324 Ma or .324 Amps.
This same equation can be used for PS250 and PS500 fixtures just substitute the Current for each Color using the table below.
|
Current required For each Color
|
|
PS250
|
330 Ma
|
|
PS500
|
566 Ma
|
Note: Equations are estimated run time and can vary depending on battery efficiency and age. Calculation are also based on battery at full charge and runtime ending when battery is at 10% charged. When battery reaches 20% charged there will be a small voltage drop in the battery which will decrease the intensity of the LED fixture.